Commercial Grade Ground Fault Receptacle, 20 Amps, 125 Volts, Brown, NEMA 5-20R
(Pack of
1)
SKU:15509 Item#: 15509
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Couldn't load pickup availability
Catalog page#: 17-88
Frequently Bought Together
Ring Tongue Terminal 16 to 14 AWG Blue
Couldn't load pickup availability
Socket Contact 20-16 AWG Size 16
Couldn't load pickup availability
ATO/ATC Fuse 30A Green
Couldn't load pickup availability
Toggle Switch AC Single Pole 20A 125/277V Ivory
Couldn't load pickup availability
Hospital Grade Duplex Receptacle 15A 125V Ivory
Couldn't load pickup availability
Quad Receptacle with Surge Protection Blue
Couldn't load pickup availability
SAE Flat Washer Thru-Hardened Steel 3/8"
Couldn't load pickup availability
Cable Tie 11.41" Black
Couldn't load pickup availability
Vision Pro Super
Couldn't load pickup availability
Disconnect Switch SPST 36VDC On/Off
Couldn't load pickup availability
Weather Protected Connector Boot 2 Pole 3 Wire 30A
Couldn't load pickup availability
Industrial Duty Plug 20A 125V L5-20P
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
| Item#: | 15509 |
|---|---|
| Style | LED Ground Fault Receptacle |
| Volts | 125 |
| NEMA Configuration | 5-20R |
| Color | Brown |
| Approvals | UL 943 Standard, CSA |
| Type | Plugs, Connectors and Receptacles |
| UNSPSC #: | 39121400 |
| TAA Compliant: | No |
| Weight: | 0.33 lb |