Ground Fault Receptacle 20A 125V Brown
(Pack of
1)
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Frequently Bought Together

ATO/ATC Fuse 20A Yellow
Couldn't load pickup availability

Female Quick Slide Terminal 22 to 18 AWG Clear
Couldn't load pickup availability

Nylon Cable Tie 6" Black
Couldn't load pickup availability

Hospital Grade Angle Plug 15A 125V
Couldn't load pickup availability

Thermoplastic Plug 15A 125V Yellow
Couldn't load pickup availability

Industrial Duty Locking Connector 20A 125/250V
Couldn't load pickup availability

USS Flat Washer Thru-Hardened Steel 3/8"
Couldn't load pickup availability

Rechargeable Penlight Flashlight
Couldn't load pickup availability

SAE Flat Washer Thru-Hardened Steel 3/8"
Couldn't load pickup availability

Locking Plug 2-Pole 3-Wire 15A 125V
Couldn't load pickup availability

Locking Receptacle 15A 125V
Couldn't load pickup availability

Rocker Switch SPST, 14V DC 20A , 28V DC 10A, Black Screw Term Sqr (On)
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
Item#: | 15509 |
---|---|
Style | LED Ground Fault Receptacle |
Volts | 125 |
NEMA Configuration | 5-20R |
Color | Brown |
Approvals | UL 943 Standard, CSA |
Type | Plugs, Connectors and Receptacles |
UNSPSC #: | 39121400 |
TAA Compliant: | No |
Weight: | 0.33 lb |
Product Restrictions

