Commercial Grade Ground Fault Receptacle, 20 Amps, 125 Volts, White, NEMA 5-20R
(Pack of
1)
SKU:15511 Item#: 15511
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Couldn't load pickup availability
Catalog page#: 17-88
Frequently Bought Together
Tru-Shrink Heat Shrink Tubing 8 to 1 AWG Black
Couldn't load pickup availability
Super 33+ Series Vinyl Electrical Tape Black 3/4"
Couldn't load pickup availability
MINI Fuse 30A Green
Couldn't load pickup availability
Quad Receptacle
Couldn't load pickup availability
Industrial Duty SAF-T Connect Plug 15A 125V
Couldn't load pickup availability
SAF-T Ground and Continuity Monitor Plug 15A 125V
Couldn't load pickup availability
Utility Knife, Folding , 4" Closed
Couldn't load pickup availability
Stepdown Butt Connector 16 to 14/12 to 10 AWG
Couldn't load pickup availability
Hex Nut Grade 8 Alloy Steel 1/2-13
Couldn't load pickup availability
Industrial Duty Connector 20A 125V
Couldn't load pickup availability
Universal Toggle Switch SPST 6A 125V On-Off
Couldn't load pickup availability
Toggle Switch SPST 20A 12V On-Off
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
| Item#: | 15511 |
|---|---|
| Style | LED Ground Fault Receptacle |
| Volts | 125 |
| NEMA Configuration | 5-20R |
| Color | White |
| Approvals | UL 943 Standard, CSA |
| Type | Plugs, Connectors and Receptacles |
| UNSPSC #: | 39121400 |
| TAA Compliant: | No |
| Weight: | 0.36 lb |