JTD Series Class J Indicator Fuse, 10 Amps, 600 Volts, Time Delay
(Pack of
1)
SKU:19885 Item#: 19885
Indicator fuses provide visual blown fuse indication at a glance
Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Interrupting rating: 200,000A rms symmetrical; 300,000A rms symmetrical (UL listed Special Purpose) UL listed Class J Fuses per UL 198C CSA certified HRCI-J per C22.2 #106 Meets Federal Specification WF1814 (QPL)
Provide space-saving protection for service entrance, main, feeder and general-purpose branch circuits
Time-delay characteristics and high current limitation mean the JTD fuse is also used in the protection of circuits with high-inrush currents such as motors, transformers and solenoids, including both IEC-rated and NEMA-rated devices
Fuses 100A and higher have blade ends
Frequently Bought Together
Cable Tie 11.41" Black
Couldn't load pickup availability
Cable Tie 13.38" Black
Couldn't load pickup availability
Cable Tie 7.31" Black
Couldn't load pickup availability
MAXI® Fuse 40A Orange
Couldn't load pickup availability
ATO/ATC In-Line Fuse Holder with Cap 32V 25-35A
Couldn't load pickup availability
ATO/ATC Fuse 40A Orange
Couldn't load pickup availability
KLKR Series Class CC Fuse 30A
Couldn't load pickup availability
FLNR Series Class RK5 Indicator Fuse 70A
Couldn't load pickup availability
FLSR Series Class RK5 Indicator Fuse 25A
Couldn't load pickup availability
SAE Flat Washer Thru-Hardened Steel 3/8"
Couldn't load pickup availability
Lawson Open & Shut Nut & Bolt Loosener, Rust Penetrant, SKU DA6152, 20 oz Aerosol Can
Couldn't load pickup availability
SAE J995C Locknut with Nylon Insert Grade 8 1/4-20
Couldn't load pickup availability
Product Description
Indicator fuses provide visual blown fuse indication at a glance Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Interrupting rating: 200,000A rms symmetrical; 300,000A rms symmetrical (UL listed Special Purpose) UL listed Class J Fuses per UL 198C CSA certified HRCI-J per C22.2 #106 Meets Federal Specification WF1814 (QPL)
Provide space-saving protection for service entrance, main, feeder and general-purpose branch circuits
Time-delay characteristics and high current limitation mean the JTD fuse is also used in the protection of circuits with high-inrush currents such as motors, transformers and solenoids, including both IEC-rated and NEMA-rated devices
Fuses 100A and higher have blade ends
Technical Specifications
| Item#: | 19885 |
|---|---|
| Style | JTD, Class J Fuses, Non-Indicator Series |
| Amperage | 10 A |
| Approvals | UL, CSA |
| Type | Fuses |
| Bussman Number | LPJ-10SP |
| UNSPSC #: | 39121627 |
| TAA Compliant: | Yes |
| Weight: | 0.09 lb |