Commercial Grade Ground Fault Receptacle, 20 Amps, 125 Volts, Ivory, NEMA 5-20R
(Pack of
1)
SKU:15510 Item#: 15510
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Couldn't load pickup availability
Catalog page#: 17-88
Frequently Bought Together
Butt Connector 16 to 14 AWG Blue
Couldn't load pickup availability
Nylon Cable Tie 4" Black
Couldn't load pickup availability
Stepdown Butt Connector 22 to 18/16 to 14 AWG
Couldn't load pickup availability
Ground Fault Receptacle 20A 125V Brown
Couldn't load pickup availability
Ground Fault Receptacle 20A 125V White
Couldn't load pickup availability
Industrial Duty SAF-T Connect Plug 15A 125V
Couldn't load pickup availability
High Solids Paints Gloss Black
Couldn't load pickup availability
Waterproof Work Aqua Light 66 LED
Couldn't load pickup availability
Butt Connector 16 to 14 AWG Blue
Couldn't load pickup availability
Ground Fault Receptacle 15A 125V White
Couldn't load pickup availability
Toggle Switch SPST 35A 6V Off-On
Couldn't load pickup availability
Ground Fault Receptacle 20A 125V Brown
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
| Item#: | 15510 |
|---|---|
| Style | LED Ground Fault Receptacle |
| Volts | 125 |
| NEMA Configuration | 5-20R |
| Color | Ivory |
| Approvals | UL 943 Standard, CSA |
| Type | Plugs, Connectors and Receptacles |
| UNSPSC #: | 39121400 |
| TAA Compliant: | No |
| Weight: | 0.37 lb |