JTD Series Class J Indicator Fuse, 25 Amps, 600 Volts, Time Delay
(Pack of
1)
SKU:19888 Item#: 19888
Indicator fuses provide visual blown fuse indication at a glance
Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Interrupting rating: 200,000A rms symmetrical; 300,000A rms symmetrical (UL listed Special Purpose) UL listed Class J Fuses per UL 198C CSA certified HRCI-J per C22.2 #106 Meets Federal Specification WF1814 (QPL)
Provide space-saving protection for service entrance, main, feeder and general-purpose branch circuits
Time-delay characteristics and high current limitation mean the JTD fuse is also used in the protection of circuits with high-inrush currents such as motors, transformers and solenoids, including both IEC-rated and NEMA-rated devices
Fuses 100A and higher have blade ends
Couldn't load pickup availability
California Proposition 65: WARNING: Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
Catalog page#: 17-119
Frequently Bought Together
Nylon Cable Tie 15.5" Black
Couldn't load pickup availability
Butt Connector 16 to 14 AWG Clear
Couldn't load pickup availability
Butt Connector 22 to 18 AWG Clear
Couldn't load pickup availability
MINI Fuse 30A Green
Couldn't load pickup availability
MINI Fuse 15A Blue
Couldn't load pickup availability
MINI Fuse 10A Red
Couldn't load pickup availability
CCMR Series Class CC Fuse 6A
Couldn't load pickup availability
CCMR Series Class CC Fuse 30A
Couldn't load pickup availability
312 Series Glass Body Fuse 5A
Couldn't load pickup availability
Nylon Cable Tie 15.5" Black
Couldn't load pickup availability
Butt Connector 16 to 14 AWG Clear
Couldn't load pickup availability
Butt Connector 22 to 18 AWG Clear
Couldn't load pickup availability
Product Description
Indicator fuses provide visual blown fuse indication at a glance Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Interrupting rating: 200,000A rms symmetrical; 300,000A rms symmetrical (UL listed Special Purpose) UL listed Class J Fuses per UL 198C CSA certified HRCI-J per C22.2 #106 Meets Federal Specification WF1814 (QPL)
Provide space-saving protection for service entrance, main, feeder and general-purpose branch circuits
Time-delay characteristics and high current limitation mean the JTD fuse is also used in the protection of circuits with high-inrush currents such as motors, transformers and solenoids, including both IEC-rated and NEMA-rated devices
Fuses 100A and higher have blade ends
Technical Specifications
| Item#: | 19888 |
|---|---|
| Style | JTD, Class J Fuses, Non-Indicator Series |
| Amperage | 25 A |
| Approvals | UL, CSA |
| Type | Fuses |
| Bussman Number | LPJ-25SP |
| UNSPSC #: | 39121627 |
| TAA Compliant: | Yes |
| Weight: | 0.09 lb |