Pneumatic/Electric Threshold Sensor, M5x0.8
(Pack of
1)
SKU:1198791 Item#: 1198791
The Legris sensor fitting detects the absence of pressure and translates it to a high-pressure pneumatic output. When used to monitor the decaying or exhausting side of a pneumatic cylinder’s piston, it emits a positive output. When the cylinder comes to the end of its stroke, wherever that may be, the signal emitted from the sensor can then be used to pilot the next step.
Legris sensor fittings are very compact and can be mounted on the cylinder, on the control valve or on a terminal block provided it is between the cylinder and the flow control. For accuracy, the flow control regulator should be positioned as close as possible to the cylinder. It can also be fitted to a sensor fitting mounted on the cylinder.
Senses the end of the stroke and reverses the operation of cylinder sensor on each end (blind/red) Variable end of stroke sensing capability not limited to a fixed return position Mounting flow control directly on sensor provides an additional benefit of control without adding additional fittings Pneumatic device does not require adjustment like mechanical devices Pneumatic or electric version use with air piloted valve and solenoid piloted valve No limit switch pneumatic or electrical
Models with electric output sensor: Supplied with three core 0.5mm² cable, length 2 m (6.5 ft.)
Working pressure: 0 to 115 PSI Threshold Signal Pressure: 7 PSI Sutable fluids: compressed air UL Listed Component Reset Pressure: 10 PSI Current Rating: 5A/250V AC - 5W/48V DC Cable: three core, 2m (6-1/2 ft.) long Black (NC) Blue (COMM) Brown (NO)
Exhaust pressure is sensed by a N/O, N/C contract relay switch. Pneumatic/Electric Threshold valves are ideally suited to turn on or off a light, or to send an electric signal to another function in the system. They are supplied with a 6 ft., three core cable and can be used with AC or DC voltages. Advantages for the user: Small size Replaces traditional sequence valves and/or limit switches Eliminates on going normal adjustment associated with limit valves
Sequence valve signal Pilot valve
The threshold sensor can be mounted on the cylinder, on the control valve or on a terminal block provided it is between the cylinder and the flow control. For accuracy, the flow control is mounted as close as possible to the cylinder. It can be fitted to a sensor fitting mounted on the cylinder.
Product Description
The Legris sensor fitting detects the absence of pressure and translates it to a high-pressure pneumatic output. When used to monitor the decaying or exhausting side of a pneumatic cylinder’s piston, it emits a positive output. When the cylinder comes to the end of its stroke, wherever that may be, the signal emitted from the sensor can then be used to pilot the next step.Legris sensor fittings are very compact and can be mounted on the cylinder, on the control valve or on a terminal block provided it is between the cylinder and the flow control. For accuracy, the flow control regulator should be positioned as close as possible to the cylinder. It can also be fitted to a sensor fitting mounted on the cylinder.
Senses the end of the stroke and reverses the operation of cylinder sensor on each end (blind/red) Variable end of stroke sensing capability not limited to a fixed return position Mounting flow control directly on sensor provides an additional benefit of control without adding additional fittings Pneumatic device does not require adjustment like mechanical devices Pneumatic or electric version use with air piloted valve and solenoid piloted valve No limit switch pneumatic or electrical
Models with electric output sensor: Supplied with three core 0.5mm² cable, length 2 m (6.5 ft.)
Working pressure: 0 to 115 PSI Threshold Signal Pressure: 7 PSI Sutable fluids: compressed air UL Listed Component Reset Pressure: 10 PSI Current Rating: 5A/250V AC - 5W/48V DC Cable: three core, 2m (6-1/2 ft.) long Black (NC) Blue (COMM) Brown (NO)
Exhaust pressure is sensed by a N/O, N/C contract relay switch. Pneumatic/Electric Threshold valves are ideally suited to turn on or off a light, or to send an electric signal to another function in the system. They are supplied with a 6 ft., three core cable and can be used with AC or DC voltages. Advantages for the user: Small size Replaces traditional sequence valves and/or limit switches Eliminates on going normal adjustment associated with limit valves
Sequence valve signal Pilot valve
The threshold sensor can be mounted on the cylinder, on the control valve or on a terminal block provided it is between the cylinder and the flow control. For accuracy, the flow control is mounted as close as possible to the cylinder. It can be fitted to a sensor fitting mounted on the cylinder.
Technical Specifications
| Item#: | 1198791 |
|---|---|
| Manufacturer Model #: | 7828 00 19 |
| Style | Threshold Sensor |
| Configuration | Pneumatic/Electric Threshold Sensor |
| Thread Size | M5x0.8 |
| Thread Style | Metric |
| Material | Nylon Body, Brass Bolt |
| Wrench Size | 8 mm |
| Working Pressure | 0 to 115 PSI |
| UNSPSC #: | 40183100 |
| TAA Compliant: | No |