FLSR Series Class RK5 Indicator Fuse, 1/2 Amps, 600 Volts AC, 300 Volts DC, Time Delay
(Pack of
1)
Fuses provide visual blown fuse indication at a glance
Patented state-of-the-art solid state design provides maximum reliability and superior performance in a true dual-element design
Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an FLNR_ID or FLSR_ID Indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Rated at 600V AC, 300V DC maximum
Interrupting ratings: AC 200,000A rms symmetrical, DC 20,000A
MSHA 300V DC listing
FLSR amperages below 1A do not have an indicating window due to internal space limitations.
Frequently Bought Together
Nylon Cable Tie 11.75" Black
Couldn't load pickup availability
Nylon Cable Tie 15.5" Black
Couldn't load pickup availability
Butt Connector 16 to 14 AWG Clear
Couldn't load pickup availability
MINI Fuse 10A Red
Couldn't load pickup availability
MINI Fuse 30A Green
Couldn't load pickup availability
ATO/ATC Fuse 10A Red
Couldn't load pickup availability
CCMR Series Class CC Fuse 30A
Couldn't load pickup availability
313 Series Glass Body Fuse 6/10A
Couldn't load pickup availability
CCMR Series Class CC Fuse 5A
Couldn't load pickup availability
Nylon Cable Tie 11.75" Black
Couldn't load pickup availability
Nylon Cable Tie 15.5" Black
Couldn't load pickup availability
Butt Connector 16 to 14 AWG Clear
Couldn't load pickup availability
Product Description
Fuses provide visual blown fuse indication at a glance Patented state-of-the-art solid state design provides maximum reliability and superior performance in a true dual-element design
Reduces downtime and nuisance opening, increases safety and can save thousands of dollars in lost production
A glance at the indicating window of an FLNR_ID or FLSR_ID Indicator fuse pinpoints open fuses immediately if the window is dark, the fuse has opened
No fuse testing required
Indicator fuses improve safety by minimizing exposure to live circuits; they provide built-in blown fuse indication with the power on or off
Rated at 600V AC, 300V DC maximum
Interrupting ratings: AC 200,000A rms symmetrical, DC 20,000A
MSHA 300V DC listing
FLSR amperages below 1A do not have an indicating window due to internal space limitations.
Technical Specifications
| Item#: | 60070 |
|---|---|
| Style | FLSR_ID Indicator Class RK5 Fuses |
| Amperage | 1/2 A |
| Rating | 600V AC, 300V DC maximum V |
| Type | Fuses |
| Replaces | competitors FRS-R and TRS-R non-indicating fusess |
| UNSPSC #: | 39121627 |
| TAA Compliant: | Yes |
| Weight: | 0.12 lb |
Product Restrictions