Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Frequently Bought Together

Stepdown Butt Connector 22 to 18/16 to 14 AWG
Couldn't load pickup availability

Rechargeable Penlight Flashlight
Couldn't load pickup availability

Superbutt Connector 22 to 18 AWG Red
Couldn't load pickup availability

SAF-T Ground and Continuity Monitor Plug 15A 125V
Couldn't load pickup availability

Industrial Duty Locking Connector 20A 125V
Couldn't load pickup availability

Locking Plug 2-Pole 3-Wire 15A 125V
Couldn't load pickup availability

Butt Connector 16 to 14 AWG Blue
Couldn't load pickup availability

Vision Pro Super
Couldn't load pickup availability

Nylon Cable Tie 4" Black
Couldn't load pickup availability

Rocker Switch SPST, 14V DC 20A , 28V DC 10A, Red LED Round, On-Off
Couldn't load pickup availability

Rocker Switch DPST 25A 12VDC On-Off
Couldn't load pickup availability

Industrial Duty SAF-T Connect Plug 15A 125V
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
Item#: | 15508 |
---|---|
Style | LED Ground Fault Receptacle |
Volts | 125 |
NEMA Configuration | 5-15R |
Color | White |
Approvals | UL 943 Standard, CSA |
Type | Plugs, Connectors and Receptacles |
UNSPSC #: | 39121400 |
TAA Compliant: | No |
Weight: | 0.37 lb |