Ground Fault Receptacle 15A 125V White
(Pack of
1.0)
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off
Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Couldn't load pickup availability
California Proposition 65: Not Applicable
www.P65Warnings.ca.gov
Catalog page#: 17-88
Frequently Bought Together

Butt Connector 16 to 14 AWG Blue
Couldn't load pickup availability

MINI Fuse 10A Red
Couldn't load pickup availability

MINI Fuse 30A Green
Couldn't load pickup availability

Quad Receptacle with Surge Protection Blue
Couldn't load pickup availability

Toggle Switch AC Single Pole 20A 125/277V Brown
Couldn't load pickup availability

Wall Plate for Toggle Switch Nylon Brown
Couldn't load pickup availability

Superbutt Connector 22 to 18 AWG Red
Couldn't load pickup availability

Hex Nut Grade 8 Alloy Steel 1/2-13
Couldn't load pickup availability

USS Flat Washer Thru-Hardened Steel 5/16"
Couldn't load pickup availability

Toggle Switch SPDT 25A 12VDC
Couldn't load pickup availability

Miniature Toggle Switch SPDT 6A 125V On-None-On
Couldn't load pickup availability

Weather Protected Plug Boot 2 Pole 3 Wire 30A 250V
Couldn't load pickup availability
Product Description
Built-in LED light test feature indicates if the ground fault circuit is functioning; LED light is normally off Designed with safety in mind; if the line and load wires are miswired, there is no power to the face of the outlet or downstream, and the unit will not be able to reset
Meets the requirements of new UL 943 standard effective 7/28/06
Superior surge protection: 50 joules/250V over voltage capability, and resistant to nuisance tripping
Test Procedure: With the receptacle properly wired, press the test button. If the GFCI circuit is functional, the LED light will be OFF and the reset button will pop out. Press the reset button to re-energize. If the GFCI circuit is NOT functional, the LED light flashes red and the reset button does not pop out, indicating the receptacle should be replaced.
Technical Specifications
Item#: | 15508 |
---|---|
Style | LED Ground Fault Receptacle |
Volts | 125 |
NEMA Configuration | 5-15R |
Color | White |
Approvals | UL 943 Standard, CSA |
Type | Plugs, Connectors and Receptacles |
UNSPSC #: | 39121400 |
TAA Compliant: | No |
Weight: | 0.37 lb |
Product Restrictions
California Proposition 65: Not Applicable
www.P65Warnings.ca.gov